Measurement method |
pH |
Glass electrode method |
ORP |
Platinum electrode method |
Conductivity |
AC 2-Electrode Method |
DO |
Optical |
Temperature |
Thermistor resistor |
Display unit |
Custom LCD with backlight |
Measurement Item/Range |
pH |
pH0.000~pH14.000 |
mV(ORP) |
-2000~2000mV |
Conductivity |
0.1mS/m~10S/m |
Resistivity |
0.1 Ω?m to 10kΩ?m (converted from Conductivity) |
Salinity (NaCl, PSSs: Practical Salinity) TDS (total dissolved solid) |
Conversion from Conductivity |
DO/Saturation |
0.00~20.00mg/L or 0.0 to 200.0% |
Temperature |
0.0~100.0℃ When using DO probes: 0.0 to 50.0℃ |
Display Range |
pH |
pH-2.000~pH16.000 |
mV(ORP) |
-2200~2200mV |
Conductivity (manual/automatic range switching) |
0.000~2.000mS/m (0.00~20.00μS/cm) |
0.00~20.00mS/m (0.0~200.0μS/cm) |
0.0~200.0mS/m (0.000~2.000mS/cm) |
0.000~2.000S/m (0.00~20.00mS/cm) |
0.00~20.00S/m (0.0~200.0mS/cm) |
Switchable between SI unit (S/m) and old unit (S/cm) |
Resistivity (manual/automatic range switching) |
0.005~2.000 Ω?m (0.5~200.0Ω?cm) |
0.00~20.00 Ω?m (0.000~2.000kΩ?cm) |
0.0~200.0 Ω?m (0.00~20.00kΩ?cm) |
0.000~2.000 kΩ?m (0.0~200.0kΩ?cm) |
0.00~20.00 kΩ?m (0.000~2.000MΩ?cm) |
0.0~200.0 kΩ?m (0.00~20.00MΩ?cm) |
0.000~2.000 MΩ?m (0.0~200.0MΩ?cm) |
Switchable between SI unit (Ω?m) and old unit (Ω?cm) |
Salinity |
0.00~4.04%(NaCl) 0.00~42.40psu(PSS) |
TDS (total dissolved solid) (manual/automatic range switching) |
0~99.99/ 999.9 mg/L |
0~9.999/ 99.99/ 999.9 g/L |
DO/Saturation |
0.00~22.00mg/L or 0.0 to 220.0% |
Temperature |
-5.0~110.0℃ When using DO probes:-5.0 to 55.0℃ |
Repeatability (instrument body) |
pH |
±0.006pH |
mV(ORP) |
±2mV |
Conductivity/Resistivity Salinity/TDS (total dissolved solid) |
±0.5% FS |
DO/Saturation |
When combined with 8 mg/L±0.1mg/L or 100%±1% * MM4-DDO |
Temperature |
Within ±0.2℃ |
pH Temperature Compensation Range |
ATC (Automatic Temperature Compensation): 0 to 100.0℃ MTC (manual Temperature Compensation): 0 to 100.0℃ |
Conductivity Temperature Compensation scope |
ATC (Automatic Temperature Compensation): 0 to 100.0℃ MTC (manual Temperature Compensation): 0 to 100.0℃ OFF (no Temperature Compensation) |
Conductivity Standard Temperature Setting |
Fixed at 25℃ |
Conductivity Temperature Coe?cient (Linear) |
0~10.00%/℃ |
DO Temperature Compensation range |
ATC (Automatic Temperature Compensation): 0 to 50.0℃ |
pH calibration |
JIS pH standard solution, US standard solution up to 5-point calibration or custom-made standard solution up to 2-point calibration |
Temperature Calibration |
One-point calibration |
Performance Guaranteed Temperature, Humidity |
0 to 45℃ 20 to 90% (non-condensing) * 0 to 40℃ when the optional External Printer is used |
Waterproof structure |
IP67(1m, immersion allowed for 30 minutes) * Disabled when probes are not connected |
Data Memory |
MM-42DP: each ch 1500 data (measurement times, measurement values, Temperature) |
(When Data Memory is operated, the measured data of ch1 and ch2 are memorized simultaneously.) MM-41DP: 1500 data (measured time, measured value, Temperature) |
Calibration History Creation Function |
Main unit side: Last 1 time |
Probe side: pH is 10 batches including the newest, and DO is 8 batches including the newest. |
Interval Measurement function ※1 |
Setting interval: 1 second to 99 minutes 59 seconds or 5 minutes to 99 hours 59 minutes can be arbitrarily set. |
Print Function |
Can be connected to optional External Printer EPS-P30 (Plain Paper Print) |
Auto Hold Function |
Stable judgment value: Fixed |
Auto Power O? |
OFF/10 min./30 min./60 min./180 min./360 min./720 min. settable |
USB (peripheral, Micro) |
1 port standerd equipment (isolated) |
Analog output (insulate)※2 |
pH |
pH0~14 → 500~1900mV |
mV(ORP) |
-2000~2000mV → 200~2200mV |
Conductivity/Resistivity |
Each range 0~FS(2000 digit)→ 200~2200 mV |
Salinity (NaCl equivalent) |
0.00~4.00% → 200~2200mV |
Salinity (PSS-78 equivalent) |
0.00~40.00psu → 200~2200mV |
TDS |
Each range 0~FS(9999 digit)→ 200~2200 mV |
DO |
0.00~20.00mg/L → 200~2200mV |
Saturation |
0~200% → 200~2200mV |
Temperature |
0~100℃ → 200~2200mV |
Power supply |
AA batteries/rechargeable nickel-metal hydride batteries 2 pcs or USB-powered (no recharging function) ※2 |
Battery life (estimate) |
When a pH or ORP probe is connected: Approx.800 hours When a Conductivity probe is connected: Approx. 500 hours When an optical DO probe is connected: Approx. 60 hours ※2 |
|
*Backlight turns o?, option not connected |
Power consumption |
0.2VA (with battery 3V), 0.9VA (with USB-powered) |
Dimensions (projections not included) |
Approx. 70 (W) × 35 (H) × 185 (D) mm |
Main Unit Weight (including batteries) |
MM-42DP: Approx. 300g MM-41DP: Approx. 290g |