您好,欢迎来到化工原料网! [登录] [免费注册]
化工原料网
位置:首页 > 半岛游戏平台官网入口网址 > 固相萃取装置、固相萃取仪
CTC自动固相微萃取装置
CTC自动固相微萃取装置图片
型号:CTC
品牌:瑞士CTC
交货期:一个月
产地:瑞士
自动程度:全自动
通道数量:单通道
萃取类型:柱萃取


半岛bd体育手机客户端 介绍

液体样品自动进样、静态顶空自动进样、大体积顶空进样、自动固相微萃取、自动液-液萃取、在线样品衍生、热解析和直接热解析。支持以下气相: Agilent5890/6890/6850 Thermo Trace2000/GC8000top Varian GC/3400/3600/3800/3900 Shimadzu GC14/17/2010 PE Autosystem XL/Clarus 500 支持以下色谱工作站: Agilent Chemstation DataApex Clarity Dionex Chromeleon EZChrom E lite/Ezstart Justice Software Shromperfect Leco Chrom TOF Shimadzu GC/GCMSsolution Shimadzu Class VP Therom ChromQuest Therom Xcalibur Varian Star/Galaxie Waters Masslynx XYZ进样方式 模块化设计 大体积进样技术无样品定量环 可按需要制 高效率的样品进样无传输管道 各模块更换便捷 与主流GC/GC-MS 无切换阀 系统无缝兼容

Solid phase microextraction, or SPME, is a sample preparation technique used both in the laboratory and on-site. Developed in the early 1990s at the University of Waterloo by Dr. Pawliszyn's group, it is a simple and inexpensive technique where the use of solvents is not necessary.

SPME can be thought of as a very short gas chromatography column turned inside out. SPME involves the use of a fiber coated with an extracting phase, that can be a liquid (polymer) or a solid (sorbent), which extracts different kinds of analytes (including both volatile and non-volatile) from different kinds of media, that can be in liquid or gas phase. The quantity of analyte extracted by the fiber is proportional to its concentration in the sample so long as equilibrium is reached or, in case of short time pre-equilibrium, with help of convection or agitation. After extraction, the SPME fiber is transferred to the injection port of separating instruments, such as a Gas Chromatograph, where desorption of the analyte takes place and analysis is carried out.

The attraction of SPME is that the extraction is fast and simple and can be done without solvents, and detection limits can reach parts per trillion (ppt) levels for certain compounds. SPME also has great potential for field applications; on-site sampling can be done even by nonscientists without the need to have a GC-MS at each location. When properly stored, samples can be analyzed days later in the laboratory without significant loss of volatiles.


Solid phase microextraction is a fast, solvent less alternative to conventional sample extraction techniques. In SPME, analytes establish equilibria among the sample matrix, the headspace above the sample, and a polymer-coated fused fiber, then are desorbed from the fiber to a chromatography column. Because analytes are concentrated on the fiber, and are rapidly delivered to the column, minimum detection limits are improved and resolution is maintained. SPME is compatible with analyte separation/detection by gas chromatography or HPLC, and provides linear results for wide concentrations of analytes.


SPME is an equilibrium process based upon Fick’s 1st law of diffusion


SPME is a technique where the sample is incubated or agitated to equilibrate the headspace. A SPME fiber is then introduced to the headspace for a predetermined period of time. The SPME fiber is then transferred to a hot GC injection port. Analytes that were adsorbed to the fiber from the sample headspace are desorbed directly in the GC inlet. SPME fibers are a distributed by Supleco and are available in a wide variety of polarities. By matching fiber polarity with target analyte characteristics, the analysis can be optimized for improved sensitivity and performance.


SPME extraction for heated and agitated samples
For use with standard SUPELCO SPME fibers
Septumless Injector and SPME liners recommended

 

SPME offers some important advantages:

  • Single Step Extraction - reduces sample preparation time by 70%

  • Versatility - various selectivities available, adapts to any GC or HPLC system, can be automated

  • Efficient & Economical - little/no use of solvents, quantitative method, allows more than 50 extractions per fiber on average

Comparison of SPME to SPE

SPE exhaustively extracts all of the analytes, but they are diluted during elution 1mL of sample containing 1µg/mL of analyte passed through tube, eluted with 1mL of solvent = 1µg/mL X 1µl injection = 1ng (Concentrating to 100µl or injecting 10µl = 10ng on column

SPME partially extracts analytes but desorbs the entire amount 1mL sample containing 1µg/mL of analyte extracted with fiber. 1% goes on fiber. 0.01 x 1µg = 10ng desorbed on column 

用户评论
半岛bd体育手机客户端 评分
目前评分共0人
半岛bd体育手机客户端 质量
售后服务
易用性
性价比
半岛bd体育手机客户端 评论
已有0条评论
可以输入500字 
暂无评论!
瑾恒半岛游戏平台官网入口网址 (上海)有限公司
电话: 点击&查看
联系人: 吴圣明
邮编: 201204
地址: 上海市浦东新区沪南公路3419号D座1617室
同品牌半岛bd体育手机客户端 :
相关半岛bd体育手机客户端 :
猜您感兴趣
换一批
PSA制氮机
TG16G高速离心机
ePet Nxt电动移液器
TDR-30S多功能智能双温区消解仪
1000℃一体型马弗炉1.5-10T/TP
来访登记
关闭
请留下您的联系方式,登记完成即可查看电话与供应商联系,或等候供应商联系您。
留言类型:
     
*姓名:
*电话:
*单位:
Email:
*留言内容:
请说明需求数量,型号规格以及纯度含量等要求。
*验证码:
 
Baidu
map