您好,欢迎来到半岛电竞官方网址 ! [ 登录] [ 免费注册]
半岛电竞官方网址
位置: 首页> 品牌> SUPELCO> TCLP Metals in Soil-PT

TCLP Metals in Soil-PT

品牌
Supelco
货号
SPE005
规格纯度
Proficiency Testing Material
价格
2903.84 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
- +
半岛bd体育手机客户端 名称:
TCLP Metals in Soil-PT
Toxicity Characteristic Leaching Procedure Metals in Soil
半岛bd体育手机客户端 介绍:

半岛bd体育手机客户端 说明

一般描述

TCLP Metals in Soil proficiency testing material is produced in accordance with ISO/IEC 17043:2010. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.

Supelco?is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. We are the world leader in the manufacturing of real-world soil and sediment PT products.

Type of PT Scheme:Solids/Soils/Hazardous Waste

Matrix:Soil

Analyte/s:Values of analytes vary lot to lot.

All information regarding the use of TCLP Metals in Soil - PT can be found in the reporting packet which will be available to download at PT Portal.

应用

TCLP Metals in Soil - PT is a soil/hazardous waste proficiency testing material, suitable for testing TCLP metals in soil samples.

Our soil PT samples behave as real samples; and, unless there is no alternative, are not simply spikes added to a blank soil. They are designed to meet the requirements of national, regional and state-specific accreditation bodies (TNI, USEPA, UKAS) for quality assurance and continuous improvement.

Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.

特点和优势

We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

  • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
  • provide a comparison of performance with that of other laboratories, nationally and internationally
  • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
  • provide an independent evaluation of laboratory performance
  • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

制备说明

Description

  • The PT sample is suitable for analysis for the eight TCLP metals.
  • A total sample size of 225 g is provided.
  • The PT sample has been sterilized.
  • Once opened sample should be used within 6 months or by the expiration date on the label, whichever is sooner.
  • The evaluation of results will be based on study statistics for equivalent methods.
  • At least two analytes are above the regulatory limit. Some analytes may not be present at recoverable levels.

Sample Preparation

  • Extraction Procedure: Thoroughly mix the sample and extract an accurately weighed portion (approximately 100 grams) of the material using SW846 Method 1311; Toxicity Characteristic Leaching Procedure. Prepare the extract for metals analysis by using the appropriate digestion procedure for the analysis technique selected. The sample may be analyzed by any combination of inductively coupled plasma (ICP) and atomic absorption (AA) methods.
  • Provide all the requested information. Do not correct the analytical results for matrix spike recovery bias.
  • Digestion Procedures: Prepare the TCLP extracts for metals analysis using the methods for which you are seeking accreditation. There is sufficient TCLP extract to perform all digestions. If a sample digestate contains particulates that may clog your instrument, remove them by filtration, or by centrifugation (see appropriate method for guidance).
  • Analyze the digestate solutions using the appropriate determinative methods for which you are seeking accreditation.
  • The method used must be reported for each analyte.

储存及稳定性

Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.

其他说明

Are you new to Supelco?Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.

Proficiency Testing Schedule (2021-2022)

Soils
LPTP21-S2April 7 - May 21, 2021
LPTP21-S4 October 6 - November 19, 2021

LPTP22-S2April 6 - May 20, 2022
LPTP22-S4 October 5 - November 18, 2022

法律信息

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

基本信息

NACRES NA.24

半岛bd体育手机客户端 性质

质量水平 100
包装 pkg of 1 × 225 g
基质 soil
application(s) environmental
格式 matrix material

安全信息

象形图 GHS07GHS08GHS09
警示用语: Danger
危险声明 H317 - H350 - H410
预防措施声明 P202 - P261 - P273 - P280 - P302 + P352 - P308 + P313
危险分类 Aquatic Acute 1 - Aquatic Chronic 2 - Carc. 1B - Skin Sens. 1
储存分类代码 6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK WGK 3
闪点(F) Not applicable
闪点(C) Not applicable

SUPELCO

推荐半岛bd体育手机客户端
Baidu
map