您好,欢迎来到半岛电竞官方网址 ! [ 登录] [ 免费注册]
半岛电竞官方网址
位置: 首页> 品牌> SUPELCO> Inland silverside (Menidia beryllina), 48-hr Acute, nonrenewal, 25℃, SSW

Inland silverside (Menidia beryllina), 48-hr Acute, nonrenewal, 25℃, SSW

品牌
Supelco
货号
WET044
规格纯度
Proficiency Testing Material
价格
1307.29 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
- +
半岛bd体育手机客户端 名称:
Inland silverside (Menidia beryllina), 48-hr Acute, nonrenewal, 25℃, SSW
半岛bd体育手机客户端 介绍:

半岛bd体育手机客户端 说明

一般描述

This Whole Effluent Toxicity (WET) proficiency testing sample is produced in accordance with ISO/IEC 17043:2010. This sample is manufactured according to TNI requirements. However, please note, this sample may include non-TNI analytes as well.

In acute WET tests, inland silverside,Menidia beryllina, is employed as a test organism and exposed to various effluent concentrations under controlled conditions for a short duration (48 h). This helps to estimate the effluent′s toxicity and arrive at the lethally toxic concentrations of the effluent.

Supelco?is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our PT program is designed to meet the quality assurance requirements in compliance with Discharge Monitoring Report - Quality Assurance Program (DMR-QA), thereby ensuring the analytical competence of your laboratory.

Analyte/s:Values of analytes vary lot to lot.

All information regarding the use of Inland silverside (Menidia beryllina), 48-hr Acute, nonrenewal, 25℃, SSW proficiency testing standard can be found in the reporting packet which will be available to download at PT Portal.

应用

Inland silverside (Menidia beryllina), 48-hr Acute, nonrenewal, 25℃, SSW proficiency testing material is designed for use in Acute Whole Effluent Toxicity (WET) proficiency testing.

Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.

特点和优势

We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.
Our proficiency testing (PT) program is a benchmark to:

  • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
  • provide a comparison of performance with that of other laboratories, nationally and internationally
  • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
  • provide an independent evaluation of laboratory performance
  • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

制备说明

Description

  • The effluent is provided as a concentrate for dilution in synthetic seawater.
  • This concentrate is an EPA-specified toxicant in reagent-grade DI water.
  • Enough material has been provided to run the method at least twice. If you require more toxicant please contact ptservice@milliporesigma.com. An ampule is provided for making fresh effluents for each day of the test.
  • Do not deviate from the supplied instructions or EPA Method 2006.0. Contact ptservice@milliporesigma.com before running the test if you see the need to deviate from the test conditions.
  • Deviations may affect your final evaluation

Preparation Instructions
  • To prepare 1 L of effluent, add 900 mL of synthetic seawater to a volumetric flask.
  • Preparation instructions for synthetic seawater can be found in the EPA document EPA-821-R-02-012, page 31.
  • Transfer the entire contents of one ampule to the flask.
  • Rinse the ampule with synthetic seawater and transfer to the volumetric flask. Bring flask to 1 L volume with synthetic seawater.
  • This represents 1 L of effluent water for the test.

Required Test Conditions
  • Test Type: Static non-renewal
  • Test duration: 48 hours
  • Temperature: 25 ?C ±1 ?C
  • The test must not deviate by more than 3 ?C during the test.
  • Renewal of Test solutions: non-renewal
  • Dilution water: Synthetic seawater.

Test Conditions
  • Light quality: Ambient laboratory illumination (recommended)
  • Light intensity: 10-20 μE/m2/s (50-100 ft-c) (ambient laboratory levels) (recommended)
  • Photoperiod: 16 h light, 8 h darkness (recommended)
  • Test chamber size: 250 mL (recommended minimum)
  • Test solution volume: 200 mL (recommended minimum)
  • Renewal of test solutions: After 48 h (required minimum)
  • Age of test organisms: 9-14 days; less than or equal to 24-h range in age (required)
  • No. of organisms per test chamber: 10 for effluent and receiving water tests (required minimum)
  • No. of replicate chambers per concentration: 2 for effluent tests (required minimum) 4 for receiving water tests (required minimum)
  • No. of organisms per concentration: 20 for effluent tests (required minimum) 40 for receiving water tests (required minimum)
  • Feeding regime:Artemia naupliiare made available while holding prior to the test
  • Test chamber cleaning: Cleaning not required
  • Test solution aeration: None, unless DO concentration falls below 4.0 mg/L; rate should not exceed 100 bubbles/min (recommended)
  • Test concentrations: Effluents: 5 and a control (required minimum)
  • Dilution series: Effluents: >=0.5 dilution series (recommended)
  • Endpoint: Effluents: Mortality (required)
  • Test acceptability criterion: 90% or greater survival in controls (required)

储存及稳定性

  • Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
  • If storage conditions are not provided on the label, it is intended for room temperature storage.

其他说明

Are you new to Supelco?Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.

Whole Effluent Toxicity (WET) tests are designed to predict the impact and toxicity of effluents discharges.

Proficiency Testing Schedule (2021-2022)


DMR-QA (US customers only)
DMR-QA 41 March 19 - July 5, 2021

DMR-QA 42 2022 Dates TBD

法律信息

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

基本信息

NACRES NA.24

半岛bd体育手机客户端 性质

质量水平 100
包装 ampule of 2 × 2 mL
浓度 in water
application(s) environmental
格式 matrix material

安全信息

储存分类代码 12 - Non Combustible Liquids
WGK WGK 1
闪点(F) Not applicable
闪点(C) Not applicable