您好,欢迎来到半岛电竞官方网址 ! [ 登录] [ 免费注册]
半岛电竞官方网址
位置: 首页> 品牌> Sigma-Aldrich> IROA TruQuant IQQ Workflow Kit

IROA TruQuant IQQ Workflow Kit

品牌
Sigma-Aldrich
货号
WORKFLOW
规格纯度
Supplied by IROA Technologies
价格
2343.01 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
- +
半岛bd体育手机客户端 名称:
IROA TruQuant IQQ Workflow Kit
半岛bd体育手机客户端 介绍:

半岛bd体育手机客户端 说明

应用

TruQuant IQQ is a high-quality quantitation system for making simultaneous accurate biological measurements on several hundred biochemicals in small quantities of biological samples. This is achieved by (1) spiking a complex Internal Standard (WORKFLOW-A) into a biological sample to a) quantify all the biochemicals in the sample relative to their counterparts in the Internal Standard, b) suppression-correct each compound and c) normalize sample to sample variances; and (2) injecting the same well characterized Long-Term Reference Standard (WORKFLOW-B) to create a daily retention time (RT) library of all compounds to be found in the Internal Standard for reproducible ID, and to measure day-to-day (QA/QC) to assure reproducible instrument performance. The system is completely automated using IROA ClusterFinder?software.

IROA TruQuant IQQ Workflow Kit contains the materials and tools for the analysis of 90 experimental samples. The kit is intended to be used for mass spectrometry metabolomics applications.

特点和优势

Identification:Confidence in identifying common and new metabolites
Quantification:Comprehensive correction of analytical and biological variability for all analytes
Quality Control:Convenient and automated tools for assuring reproducibility within/across studies

  • Simultaneous metabolite identification, quantitation and platform QC
  • Accurate compound formula ID for MS alone; complete ID with addition of SWATH, or IM
  • IROA patterns discriminate peaks of biological origin from artefactual peaksallowing the removal of false data
  • IROA-based fragments have the IROA ratio pattern of their parent peaks and can be identified as such using the “peak correlation” ClusterFinder?module
  • Retention Index within the sample allows “unknowns” to be tracked with precision
  • Suppression-corrected measurements for significantly better quantitation
  • Normalizes (suppression-corrected) experimental samples to overcome day-to-day, instrument-to-instrument variances
  • ClusterFinder?software solution builds libraries, IDs/quantitates compounds and normalizes data
  • Ensures high level QC for accurate and reproducible results

其他说明

ClusterFinder?software package is distributed with and is tailored to work with the IROA TruQuant IQQ kit. A user manual and video instructions are provided.
To download the software package, click here - ClusterFinder software.
Link to the ClusterFinder?Videos below:

  • IROA Peaks Basics
  • CF Process Overview
  • CF Initiation
  • CF New Project & Add Data
  • CF Unbiased Search for IROA peaks
  • CF Preferences
  • CF Libraries & Methods
  • CF BinTree - bins are displayed as a tree
  • CF Curation 1: Untargeted - quality of the peaks
  • CF Curation 2: Cascade

To access the MS Calculator Cascade Spreadsheet, follow the link below:
MS Calculator

法律信息

ClusterFinder is a trademark of IROA Technologies LLC

半岛bd体育手机客户端 性质

运输 dry ice
储存温度 ?70℃

安全信息

储存分类代码 10 - Combustible liquids

Sigma-Aldrich

推荐半岛bd体育手机客户端
Baidu
map