您好,欢迎来到半岛电竞官方网址 ! [ 登录] [ 免费注册]
半岛电竞官方网址
位置: 首页> 品牌> Sigma-Aldrich> Opticap XL 3 Millipore Express PHF 可γ辐照 0.2 μm 1-1/2 in.TC/TC

Opticap?XL3 Millipore Express?PHF

Opticap XL 3 Millipore Express PHF 可γ辐照 0.2 μm 1-1/2 in.TC/TC

品牌
Millipore
货号
KPGEG03TT3
规格纯度
inlet connection diam. 1.5 in., pore size 0.2 μm, cartridge nominal length 3 in. (7.5 cm)
价格
5057.88 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
- +
半岛bd体育手机客户端 名称:
Opticap ?XL3 Millipore Express ?PHF
Opticap XL 3 Millipore Express PHF Gamma Compatible 0.2 μm 1-1/2 in. TC/TC
Opticap XL 3 Millipore Express PHF 可γ辐照 0.2 μm 1-1/2 in.TC/TC
半岛bd体育手机客户端 介绍:

半岛bd体育手机客户端 说明

一般描述

Device Configuration: 取样皿滤膜

包装

Double Easy-Open bag

其他说明

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS?Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS?Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

制备说明

This product was manufactured with a Millipore Express?membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable

分析说明

Bacterial Retention
Samples of membrane used in this filter were quantitatively retentive of a minimumBrevundimonas diminutachallenge concentration of 1 x 10? CFU/cm? using ASTM?F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 3.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 ?S/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L

法律信息

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

免责声明

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

半岛bd体育手机客户端 性质

质量水平 400
物料 polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
reg. compliance meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
特点 gamma compatible
hydrophilic
manufacturer/tradename Millipore Express?
参数 ≤9.5 mL/min air diffusion at 2.8 bar (40 psig) and 23 ℃ (in water)
1.0 bar max. inlet pressure (15 psi) at 80 ℃
1000 bar max. differential pressure (15 psi) at 80 ℃
2.75 bar max. inlet pressure (40 psi) at 60 ℃
25 ℃ max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 ℃
5500 mbar max. differential pressure (80 psi) at 25 ℃
80 psig max. inlet pressure
长度 17.3 cm (6.8 in.)
cartridge nominal length 3 in. (7.5 cm)
直径 10.7 cm (4.2 in.)
过滤面积 0.17 m2
inlet connection diam. 1.5 in.
inlet to outlet W 17.3 cm (6.8 in.)
outlet connection diam. 1.5 in.
总尺寸 3 in.
杂质 ≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
基质 Millipore Express?PHF
孔径 0.2 μm nominal pore size
0.2 μm pore size
配件 1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
38 mm (1 1/2 in.) inlet/outlet sanitary flange
outlet sanitary flange