The GLO annealing furnace features a vacuum tight retort with highly symmetric positioning of the heating elements. The heating elements are CrFeAl, also known as APM, and are embedded in the ceramic fibre insulation.
The GLO is often equipped with a vacuum pumping system to reduce the Oxygen levels prior to heat treatment. To ensure the lowest possible contamination levels, several cycles of vacuum and Nitrogen purging occur to create a pure atmosphere in the retort. Vacuum assisted cycling is far superior compared to simply flowing Nitrogen through the retort as the process creates a pure atmosphere faster and requires less Nitrogen. After Oxygen levels have been reduced, heat treatment begins under an inert atmosphere with a slight overpressure.
The highest possible temperature of the GLO annealing furnace is 1100℃ for heat treatment with an atmosphere. The front door of the cylindrical retort can be heated if required. At the water cooled front door, the gas is purged inside the GLO. It is preheated by the radiation shields, which are inserted at the front. The GLO is provided with a rear port for the expulsion of any gaseous by-products generated during the process.
The GLO can be operated manually or with the use of an automated system. The furnace is available in sizes of 10 (mobile version), 40, 75, 120 and 260 litres. The retort is manufactured with temperature resistant steel alloy (1.4841). Other materials are available on request.
The annealing furnace may be operated with reactive gases such as Hydrogen, which requires appropriate safety technology. The Hydrogen safety system includes an automatic operating system with a Nitrogen flooding tank to detect and purge the system should any malfunctions be detected. All devices are SIL2 certified.
The furnaces have a compact, space saving design. The debinding package allows for debinding or pyrolysis processes to be carried out. Virtually no condensation occurs as the unit is equipped with an afterburner and heated gas outlet for strong outgassing applications.
The GLO can be equipped with a fast cooling system. The retort can be air cooled from the outside or purged with cold, inert gas.
The GLO furnace is also available in two alternative versions:
Thevertical VGLOis loaded vertically and therefore provides a compact, space saving design.
Themobile GLOis a transportable, space-saving version for flexible use in different applications.
应用实例
annealing, degassing, drying, glowing, hardening, pyrolysis, tempering, thermal debinding prior to sintering
标准参数
Precisely controlled atmosphere with highest possible purity
Sealed retort for highest vacuum possible
Fast heat up and cool down options upon request
Hydrogen partial pressure operation upon request
Afterburner
Certified safety management for flammable and toxic gases
Fully automatic operation or manual operation
Data recording for quality management
选项(订购时详细标注要求)
Vacuum System: pre-vacuum pump, roots pump, or turbomolecular pump
Different software and controller options like Eurotherm 3508, Siemens, iTools, over-temperature protection or remote control available
Reaction gas equipment for hydrogen concentrations larger than 4%
Chiller in case no water cooling is available on-site
技术参数
View inside of the annealing furnace:
opened door
radiation shields
ceramic fiber insulation and heating elements
charging rack
thin metallic sourrounding
afterburner
frame
The maximum temperature of the GLO annealing furnace is 1100℃. In this temperature range, heat is transmitted via a high amount of heat convection and conduction.
To ensure excellent temperature uniformity, the furnace is equipped with a gas circulation system by means of a ventillator located at the rear of the furnace, which ensures that the sample is surrounded by uniform inert gas at all times.
The sample specimen is placed on an engineered, horizontal charging rack with the incoming gases guided over the sample. Any gaseous by-products generated are immediately flushed out of the furnace.
A probe thermocouple is positioned at the rear of the furnace and in close proximity to the samples. The probe thermocouple serves as the control thermocouple for the two heating zones of the GLO, and simultaneously, monitors the temperature directly at the sample.
The heating elements are located outside of the retort. An over-temperature thermocouple is used for unattended operation. Further thermocouple probes can be integrated into the retort upon request.
内容可能会被修改或更正。
GLO 10/11-1G
Volume (l) |
10 |
Tmax vacuum (°C) |
600 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
1800 x 850 x 1600 |
Transport weight |
|
Complete system (kg) |
500 |
Usable space |
|
? x D (mm) |
250 x 300 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 5 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
4 - 5 |
Connecting values |
|
Power (kW) |
14 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 25 |
Series fuse (A) |
3 x 32 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
1-3 |
Max. inlet temperature (°C) |
23 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
200-2000 |
Controller |
|
Manual operation |
Eurotherm |
Automatic operation |
Siemens |
VGLO-TL 10/11-1G
Volume (l) |
10 |
Tmax vacuum (°C) |
600 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
1600 (open) x 1400 x 850 |
Transport weight |
|
Complete system (kg) |
500 |
Usable space |
|
? x D (mm) |
250 x 250 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 5 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
4 - 5 |
Connecting values |
|
Power (kW) |
14 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 25 |
Series fuse (A) |
3 x 32 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
1-3 |
Max. inlet temperature (°C) |
23 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
200-2000 |
Controller |
|
Manual operation |
Eurotherm |
Automatic operation |
Siemens |
GLO 40/11-1G
Volume (l) |
40 |
Tmax vacuum (°C) |
600 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
1900 x 1400 x 1800 |
Transport weight |
|
Complete system (kg) |
1200 |
Usable space |
|
? x D (mm) |
300 x 600 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 3 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
7 - 9 |
Connecting values |
|
Power (kW) |
25 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 63 |
Series fuse (A) |
3 x 80 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
1-3 |
Max. inlet temperature (°C) |
23 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
200-2000 |
Controller |
|
Manual operation |
Eurotherm with KP 300 panel |
Automatic operation |
Siemens |
GLO 75/11-1G
Volume (l) |
75 |
Tmax vacuum (°C) |
600 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
2000 x 1600 x 1800 |
Transport weight |
|
Complete system (kg) |
1500 |
Usable space |
|
? x D (mm) |
400 x 600 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 3 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
7 - 9 |
Connecting values |
|
Power (kW) |
40 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 110 |
Series fuse (A) |
3 x 160 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
1-3 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
200-2000 |
Controller |
|
Manual operation |
Eurotherm with KP 300 panel |
Automatic operation |
Siemens |
GLO 120/11-1G
Volume (l) |
120 |
Tmax vacuum (°C) |
600 / 750 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
2100 x 1800 x 2000 |
Transport weight |
|
Complete system (kg) |
2000 |
Usable space |
|
? x D (mm) |
500 x 700 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 5 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
8 - 10 |
Connecting values |
|
Power (kW) |
45 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 67 |
Series fuse (A) |
3 x 80 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
5-10 |
Max. inlet temperature (°C) |
23 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
200-3000 |
Controller |
|
Manual operation |
Eurotherm with KP 300 panel |
Automatic operation |
Siemens |
GLO 260/11-1G
Volume (l) |
260 |
Tmax vacuum (°C) |
600 / 750 |
Tmax atmospheric pressure (°C) |
600 / 900 / 1100 |
尺寸: 外部 高 x 宽 x 纵深 (mm) |
2100 x 1800 x 2000 |
Transport weight |
|
Complete system (kg) |
3000 |
Usable space |
|
? x D (mm) |
650 x 800 |
Thermal values |
|
ΔT between 300 and 1100°C (K) according to DIN 17052 |
± 5 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
10 - 12 |
Connecting values |
|
Power (kW) |
70 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 110 |
Series fuse (A) |
3 x 125 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine or high vacuum |
Cooling water required |
|
Flow (l/min) |
10-15 |
Max. inlet temperature (°C) |
23 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
300-3000 |
Controller |
|
Manual operation |
Eurotherm with KP 300 panel |
Automatic operation |
Siemens |