Measurement method |
pH |
Glass electrode method |
ORP |
Platinum electrode method |
Conductivity |
AC 2-Electrode Method |
DO |
Optical |
Temperature |
Thermistor resistor |
Display unit |
Custom LCD with backlight |
Measurement Item/Range |
pH |
pH0.000锝瀙H14.000 |
mV(ORP) |
-2000锝?000mV |
Conductivity |
0.1mS/m锝?0S/m |
Resistivity |
0.1 惟?m to 10k惟?m (converted from Conductivity) |
Salinity (NaCl, PSSs: Practical Salinity) TDS (total dissolved solid) |
Conversion from Conductivity |
DO/Saturation |
0.00锝?0.00mg/L or 0.0 to 200.0% |
Temperature |
0.0锝?00.0鈩 When using DO probes: 0.0 to 50.0鈩傸/span> |
Display Range |
pH |
pH-2.000锝瀙H16.000 |
mV(ORP) |
-2200锝?200mV |
Conductivity (manual/automatic range switching) |
0.000锝?.000mS/m (0.00锝?0.00渭S/cm) |
0.00锝?0.00mS/m (0.0锝?00.0渭S/cm) |
0.0锝?00.0mS/m (0.000锝?.000mS/cm) |
0.000锝?.000S/m (0.00锝?0.00mS/cm) |
0.00锝?0.00S/m (0.0锝?00.0mS/cm) |
Switchable between SI unit (S/m) and old unit (S/cm) |
Resistivity (manual/automatic range switching) |
0.005锝?.000 惟?m (0.5锝?00.0惟?cm) |
0.00锝?0.00 惟?m (0.000锝?.000k惟?cm) |
0.0锝?00.0 惟?m (0.00锝?0.00k惟?cm) |
0.000锝?.000 k惟?m (0.0锝?00.0k惟?cm) |
0.00锝?0.00 k惟?m (0.000锝?.000M惟?cm) |
0.0锝?00.0 k惟?m (0.00锝?0.00M惟?cm) |
0.000锝?.000 M惟?m (0.0锝?00.0M惟?cm) |
Switchable between SI unit (惟?m) and old unit (惟?cm) |
Salinity |
0.00锝?.04%(NaCl) 0.00锝?2.40psu(PSS) |
TDS (total dissolved solid) (manual/automatic range switching) |
0锝?9.99/ 999.9 mg/L |
0锝?.999/ 99.99/ 999.9 g/L |
DO/Saturation |
0.00锝?2.00mg/L or 0.0 to 220.0% |
Temperature |
-5.0锝?10.0鈩 When using DO probes:-5.0 to 55.0鈩傸/span> |
Repeatability (instrument body) |
pH |
卤0.006pH |
mV(ORP) |
卤2mV |
Conductivity/Resistivity Salinity/TDS (total dissolved solid) |
卤0.5% FS |
DO/Saturation |
When combined with 8 mg/L卤0.1mg/L or 100%卤1% * MM4-DDO |
Temperature |
Within 卤0.2鈩傸/span> |
pH Temperature Compensation Range |
ATC (Automatic Temperature Compensation): 0 to 100.0鈩傸br/>MTC (manual Temperature Compensation): 0 to 100.0鈩傸/span> |
Conductivity Temperature Compensation scope |
ATC (Automatic Temperature Compensation): 0 to 100.0鈩傸br/>MTC (manual Temperature Compensation): 0 to 100.0鈩傸br/>OFF (no Temperature Compensation) |
Conductivity Standard Temperature Setting |
Fixed at 25鈩傸/span> |
Conductivity Temperature Coe?cient (Linear) |
0锝?0.00%/鈩傸/span> |
DO Temperature Compensation range |
ATC (Automatic Temperature Compensation): 0 to 50.0鈩傸/span> |
pH calibration |
JIS pH standard solution, US standard solution up to 5-point calibration or custom-made standard solution up to 2-point calibration |
Temperature Calibration |
One-point calibration |
Performance Guaranteed Temperature, Humidity |
0 to 45鈩 20 to 90% (non-condensing) * 0 to 40鈩 when the optional External Printer is used |
Waterproof structure |
IP67(1m, immersion allowed for 30 minutes) * Disabled when probes are not connected |
Data Memory |
MM-42DP: each ch 1500 data (measurement times, measurement values, Temperature) |
(When Data Memory is operated, the measured data of ch1 and ch2 are memorized simultaneously.) MM-41DP: 1500 data (measured time, measured value, Temperature) |
Calibration History Creation Function |
Main unit side: Last 1 time |
Probe side: pH is 10 batches including the newest, and DO is 8 batches including the newest. |
Interval Measurement function 鈥? |
Setting interval: 1 second to 99 minutes 59 seconds or 5 minutes to 99 hours 59 minutes can be arbitrarily set. |
Print Function |
Can be connected to optional External Printer EPS-P30 (Plain Paper Print) |
Auto Hold Function |
Stable judgment value: Fixed |
Auto Power O? |
OFF/10 min./30 min./60 min./180 min./360 min./720 min. settable |
USB (peripheral, Micro) |
1 port standerd equipment (isolated) |
Analog output (insulate)鈥? |
pH |
pH0锝?4 鈫 500锝?900mV |
mV(ORP) |
-2000锝?000mV 鈫 200锝?200mV |
Conductivity/Resistivity |
Each range 0锝濬S(2000 digit)鈫 200锝?200 mV |
Salinity (NaCl equivalent) |
0.00锝?.00% 鈫 200锝?200mV |
Salinity (PSS-78 equivalent) |
0.00锝?0.00psu 鈫 200锝?200mV |
TDS |
Each range 0锝濬S(9999 digit)鈫 200锝?200 mV |
DO |
0.00锝?0.00mg/L 鈫 200锝?200mV |
Saturation |
0锝?00% 鈫 200锝?200mV |
Temperature |
0锝?00鈩 鈫 200锝?200mV |
Power supply |
AA batteries/rechargeable nickel-metal hydride batteries 2 pcs or USB-powered (no recharging function) 鈥? |
Battery life (estimate) |
When a pH or ORP probe is connected: Approx.800 hours When a Conductivity probe is connected: Approx. 500 hours When an optical DO probe is connected: Approx. 60 hours 鈥? |
|
锛夿acklight turns o?, option not connected |
Power consumption |
0.2VA (with battery 3V), 0.9VA (with USB-powered) |
Dimensions (projections not included) |
Approx. 70 (W) 脳 35 (H) 脳 185 (D) mm |
Main Unit Weight (including batteries) |
MM-42DP: Approx. 300g MM-41DP: Approx. 290g |