[ 鐧诲綍] [ 鍏嶈垂娉ㄥ唽]
璇曞墏浠櫒缃? title=
浣嶇疆锛欬a href="/">棣栭〉> 璇曞墏鍙婅€楁潗> 鍏跺畠
SED52100 SequiTherm EXCEL? II DNA Polymerase
SED52100 SequiTherm EXCEL? II DNA Polymerase鍥剧墖
鍨嬪彿: SED52100
鍝佺墝: epicentre
鍖呰: 鍘熻杩涘彛
浜よ揣鏈烔 涓ゅ懆
浜у湴: us


浜у搧鍚嶇О
epicentre SED52100
SequiTherm EXCEL? II DNA Polymerase
浜у搧浠嬬粛
SED52100 SequiTherm EXCEL? II DNA Polymerase
浜у搧绠€浠嬶細鍖椾含涓寳鏋楁牸渚涘簲SED52100 SequiTherm EXCEL? II DNA Polymerase锛屼腑鍖楁灄鏍兼槸lucigen鎬讳唬鐞嗭紝鎻愪緵lucigen浜у搧璐у彿銆傚叾浠栧寘鎷琧ellscript鎬讳唬鐞嗭紝Biosearch technologies鎬讳唬鐞嗭紝epicentre鎬讳唬鐞嗭紝illumina鎬讳唬鐞嗭紝ICLLAB鎬讳唬鐞嗭紝ImmunoReagents鎬讳唬鐞嗐€侟/div>
浜у搧鍚嶇О:
SequiTherm EXCEL? II DNA Polymerase
璐у彿:SED52100
瑙勬牸:100 Rxns
瀛樺偍娓╁害:-20鈩傸/div>
鍝佺墝锛歭ucigen / epicentre
渚涘簲鍟嗭細涓寳鏋楁牸
浜у湴锛歶s
鍙戣揣鍦帮細鍖椾含
SED52100 SequiTherm EXCEL? II DNA Polymerase 浜у搧鎻忚堪

Applications

  • Automated sequencing of all DNA templates, including those containing difficult-to-sequence regions that cannot be resolved with other sequencing kits (Figs. 1-4).

  • 瀵规墍鏈塂NA妯℃澘杩涜鑷姩娴嬪簭锛屽寘鎷偅浜涘惈鏈夐毦浠ョ敤鍏朵粬娴嬪簭璇曞墏鐩掕В鏋愮殑闅句互娴嬪簭鍖哄煙鐨凞NA妯℃澘锛堝浘1-4锛夈€侟/span>

SequiTherm EXCEL II? Sequencing Kits for automated sequencers use the SequiTherm EXCEL II Polymerase, which improves sequencing performance with increased signal intensities and the ability to sequence through GC-rich regions. The SequiTherm EXCEL II DNA Sequencing Kits incorporate the use of betaine,* which enables sequencing of a broad range of templates, including those containing regions that are very difficult to sequence. Protocols are provided for both cycle and high-temperature isothermal (noncycle) sequencing.

鐢ㄤ簬鑷姩娴嬪簭浠殑SequiTherm EXCEL II?娴嬪簭璇曞墏鐩掍娇鐢⊿equiTherm EXCEL II鑱氬悎閰讹紝璇ラ叾鍙彁楂樻祴搴忔€ц兘锛屽悓鏃跺鍔犱俊鍙峰己搴︼紝骞惰兘澶熼€氳繃瀵屽惈GC鐨勫尯鍩熻繘琛屾祴搴忋€侟/span>SequiTherm EXCEL II DNA娴嬪簭璇曞墏鐩掔粨鍚堜簡鐢滆彍纰辩殑浣跨敤锛?鍙互瀵瑰绉嶆ā鏉胯繘琛屾祴搴忥紝鍖呮嫭閭d簺寰堥毦娴嬪簭鐨勫尯鍩熴€侟/span>鎻愪緵浜嗙敤浜庡惊鐜拰楂樻俯绛夋俯锛堥潪寰幆锛夋祴搴忕殑鏂规銆侟/span>

The kits have been optimized for use with the following DNA sequencers: LI-COR? 4000 and 4200 series Sequencers, NEN? Global IR2DNA Sequencers, ALF? DNA Sequencers, and ABI PRISM? DNA Sequencers using dye primer technology. Using primers labeled with standard sequencing dyes, the SequiTherm EXCEL II kits may also be used with ABI PRISM 373 and 377 series sequencers. The kits are not compatible with ABI capillary sequencers (ABI 310, 3100, or 3700 series) or with BigDye? technology.

璇ヨ瘯鍓傜洅缁忚繃浼樺寲锛屽彲涓庝互涓婦NA娴嬪簭浠厤鍚堜娇鐢細LI-COR?4000鍜?200绯诲垪娴嬪簭浠紝NEN?Global IR2DNA娴嬪簭浠紝ALF?DNA娴嬪簭浠拰浣跨敤鏌撴枡寮曠墿鎶€鏈殑ABI PRISM?DNA娴嬪簭浠€侟/span>浣跨敤鏍囨湁鏍囧噯娴嬪簭鏌撴枡鐨勫紩鐗╋紝SequiTherm EXCEL II璇曞墏鐩掕繕鍙笌ABI PRISM 373鍜?77绯诲垪娴嬪簭浠竴璧蜂娇鐢ㄣ€侟/span>璇ュ浠朵笌ABI姣涚粏绠℃祴搴忎华锛圓BI 310銆?100鎴?700绯诲垪锛夋垨BigDye?鎶€鏈笉鍏煎銆侟/span>

Two different kits are available for use with LI-COR? and NEN? sequencing equipment. The first kit (Cat. No. SE9101LC) contains Termination Mixes that give optimal read lengths up to about 1,000 bases and is designed for use on 25- to 41-cm gels. The second kit (Cat. No. SE9202LC) provides enhanced signal intensities in the resolution range of 1,000-1,400 bases and is ideal for users interested in obtaining the longest possible reads in conjunction with 66-cm gels, version 4.x of the BaseImagIR? software, and all versions of e-Seq? software.

鏈変袱绉嶄笉鍚岀殑濂椾欢鍙笌LI-COR?鍜孨EN?娴嬪簭璁惧涓€璧蜂娇鐢ㄣ€侟/span>绗椾釜璇曞墏鐩掞紙鐩綍鍙稴E9101LC锛夊寘鍚粓姝㈡贩鍚堢墿锛屽彲鎻愪緵闀胯揪1000涓⒈鍩虹殑鏈€浣宠鍙栭暱搴︼紝骞惰璁$敤浜?5鑷?1鍘樼背鐨勫嚌鑳躲€侟/span>绗簩涓瘯鍓傜洅锛堢洰褰曞彿SE9202LC锛夊湪1,000-1,400纰卞熀鐨勫垎杈ㄧ巼鑼冨洿鍐呮彁渚涘寮虹殑淇″彿寮哄害锛屽浜庡笇鏈涗笌66-cm鍑濊兌锛堢増鏈?.x鐨凚aseImagIR锛変竴璧疯幏寰楀敖鍙兘闀跨殑璇绘暟鐨勭敤鎴锋潵璇存槸鐞嗘兂鐨勯€夋嫨?杞欢浠ュ強鎵€鏈夌増鏈殑e-Seq?杞欢銆侟/span>


濂藉

  • 搴忓垪妯℃澘鍖呭惈鍙戝す缁撴瀯锛堝浘3锛夛紝楂楪C鎴朅T鍖哄煙锛堝浘1锛夛紝閾鹃棿閲嶉€€鐏尯鍩熸垨鏍歌嫹閰搁噸澶嶅簭鍒楋紙鍥?锛夈€侟/span>

  • 闄嶄綆鐨勮儗鏅俊鍙峰彲浜х敓鏇存竻鏅帮紝鏇村皯姝т箟鐨勫簭鍒楁暟鎹紙鍥?锛夈€侟/span>

  • 涓嶭I-COR锛孨EN鍜孉LF DNA娴嬪簭浠紙鏌撴枡寮曠墿鍜屽唴閮ㄦ爣绛撅級浠ュ強ABI PRISM鑷姩娴嬪簭浠紙鏌撴枡寮曠墿锛夊吋瀹圭殑璇曞墏鐩掋€侟/span>

  • 鍙€夌殑绛夋俯鏂规锛屽彲瀵瑰惊鐜祴搴忎笉鍒╃殑妯℃澘杩涜娴嬪簭銆侟/span>缁堟娣峰悎鐗╁寘鍚?-鑴辨爱-dGTP锛屼互鍑忓皯鍑濊兌鐢垫吵杩囩▼涓殑鏉″甫鍘嬬缉銆侟/span>

  • Sequence templates containing hairpin structures (Fig. 3), regions of high GC or AT (Fig. 1) content, areas of interstrand reannealing, or nucleotide repeats (Fig. 4).

  • Reduced background signal results in clearer, less ambiguous sequence data (Fig. 2).

  • Kits compatible with LI-COR, NEN, and ALF DNA sequencers (both dye-primer and internal label) and with ABI PRISM automated sequencers (dye-primer).

  • Optional isothermal protocol to sequence templates that are recalcitrant to cycle sequencing. Termination Mixes contain 7-deaza-dGTP to reduce band compression during gel electrophoresis.

SED52100 SequiTherm EXCEL? II DNA Polymerase 鍥句緥璇存槑锛欬/strong>

鍥?.鍥伴毦妯℃澘鐨勬帓搴忋€ 浣跨敤鏍囧噯寰幆娴嬪簭璇曞墏鐩掞紙A锛夊拰SequiTherm EXCEL?II璇曞墏鐩扡C锛圔锛夊瀵屽惈AT鐨勬ā鏉胯繘琛屾祴搴忋€傚鍥炬墍绀猴紝浣跨敤SequiTherm EXCEL II Kit-LC娑堥櫎浜嗗嚑涓墷鍥虹殑闄愪綅锛屽苟鏄撲簬璇诲彇搴忓垪銆傛牱鍝佷互G锛孉锛孴锛孋椤哄簭鍔犺浇銆傛暟鎹湪4000鍨婦NA娴嬪簭浠笂鍙鍖栥€侟/span>

鍥?. SequiTherm EXCEL?II Kit-LC澶уぇ闄嶄綆浜嗛潪鐗瑰紓鎬ц儗鏅€ 鐢ㄦ爣鍑嗗惊鐜祴搴忚瘯鍓傜洅锛圓锛夊拰SequiTherm EXCEL II璇曞墏鐩扡C锛圔锛夊璐ㄧ矑DNA妯℃澘杩涜娴嬪簭銆備娇鐢⊿equiTherm EXCEL II Kit-LC鍙互澶уぇ闄嶄綆鑳屾櫙淇″彿銆傛牱鍝佷互G锛孉锛孴锛孋椤哄簭鍔犺浇銆傛暟鎹湪4000鍨婦NA娴嬪簭浠笂鍙鍖栥€侟/span>

鍥?.褰撳叾浠栨柟娉曞け璐ユ椂锛孲equiTherm EXCEL II?DNA娴嬪簭璇曞墏鐩掑彲鎻愪緵瀹屾暣锛屾竻鏅扮殑娴嬪簭鏁版嵁銆 浣跨敤鏍囧噯寰幆娴嬪簭鏂规鍜孖RD800鏍囪鐨勫紩鐗╋紝浣跨敤SequiTherm EXCEL II DNA娴嬪簭璇曞墏鐩?LC鎴愬姛鍦版祴搴忎簡涓€涓寘鍚帹瀹氱殑24 bp鍙戝す鐜殑瓒呰灪鏃嬭川绮掋€傛暟鎹湪IR2鍨?000L DNA娴嬪簭浠紙闈㈡澘A锛変笂鍙鍖栥€備娇鐢ˋBI BigDye?缁堟瀛愬惊鐜祴搴忚瘯鍓傜洅鏃犳硶瑙f瀽鐩稿悓鐨勫尯鍩熴€傛暟鎹湪ABIPRISM?310閬椾紶鍒嗘瀽浠紙闈㈡澘B锛変笂鍙鍖栥€侟/span>

鍥?.閫氳繃鏈夐棶棰樼殑閲嶅鍖哄煙杩涜娴嬪簭銆 浣跨敤SequiTherm EXCEL?II DNA娴嬪簭璇曞墏鐩掞紝浣跨敤鏍囧噯寰幆娴嬪簭鏂规鍜屾煋鏂欐爣璁扮殑寮曠墿锛屾垚鍔熷湴瀵瑰寘鍚獹A-浜屾牳鑻烽吀閲嶅搴忓垪锛圓锛夛紝GGC涓夋牳鑻烽吀閲嶅搴忓垪锛圔锛夋垨GAAA-鍥涙牳鑻烽吀閲嶅搴忓垪锛圕锛夌殑瓒呰灪鏃嬭川绮掕繘琛屼簡娴嬪簭銆侟/span>

SED52100 SequiTherm EXCEL? II DNA Polymerase 璐у彿璇︽儏
璐у彿 灏哄

SequiTherm EXCEL?II DNA娴嬪簭璇曞墏鐩?LC鐢ㄤ簬25-41 cm鍑濊兌
SE9101LC 100涓簭鍒桙/span>
瀵逛簬LI-COR?鎴朜EN?鍏ㄧ悆IR2绾?/sup> 鎺掑簭銆侟/span>

SequiTherm EXCEL?II DNA娴嬪簭璇曞墏鐩?LC閫傜敤浜?6 cm鍑濊兌
SE9202LC 100涓簭鍒桙/span>
瀵逛簬LI-COR?鎴朜EN?鍏ㄧ悆IR2绾?/sup> 鎺掑簭銆侟/span>
鍐呭锛欬/em> SequiTherm EXCEL?II DNA鑱氬悎閰讹紝3.5X SequiTherm EXCEL?II娴嬪簭缂撳啿娑诧紝SequiTherm EXCEL?II-LC缁堟娣峰悎鐗╋紙G锛孉锛孴锛孋锛夛紝瀵圭収妯℃澘锛屽仠姝?鍔犺浇缂撳啿娑诧紝鏃犺弻鍘荤瀛愭按銆侟/span>

SequiTherm EXCEL?DNA鑱氬悎閰?
SED52100 100涓弽搴擖/span>
鍖呮嫭SequiTherm EXCEL?2娴嬪簭缂撳啿娑层€侟/span>

鍋滄/鍑濊兌涓婃牱缂撳啿娑诧紝纰辨€у搧绾㈠拰婧撮厷钃濇煋鏂橖/span>
SF81015 1.5姣崌
瀵逛簬LI-COR?锛孨EN?銆傝冻澶?00涓簭鍒椼€侟/span>

鍩烘湰鍝佺孩鏌撴枡
SA85025 2.5姣崌
瀵逛簬ALF?锛孉BI PRISM?锛孡I-COR?锛孨EN?銆傝冻澶?00涓簭鍒椼€侟/span>
Catalog No.Size
SequiTherm EXCEL? II DNA Sequencing Kit - LC for 25-41 cm gelsSE9101LC100 SequencesFor LI-COR?or NEN?Global IR2Sequencers.
SequiTherm EXCEL? II DNA Sequencing Kit - LC for 66 cm gelsSE9202LC100 SequencesFor LI-COR?or NEN?Global IR2Sequencers.Contents:SequiTherm EXCEL? II DNA Polymerase, 3.5X SequiTherm EXCEL? II Sequencing Buffer, SequiTherm EXCEL? II-LC Termination Mixes (G, A, T, C), Control Template, Stop/Loading Buffer, Sterile Deionized Water.
SequiTherm EXCEL? II DNA PolymeraseSED52100100 ReactionsIncludes SequiTherm EXCEL? II Sequencing Buffer.
Stop/Gel Loading Buffer, Basic Fuchsin and Bromophenol Blue DyesSF810151.5 mlFor LI-COR?, NEN?. Sufficient for 100 sequences.
Basic Fuchsin DyeSA850252.5 mlFor ALF?, ABI PRISM?, LI-COR?, NEN?. Sufficient for 100 sequences.
瀵规浜у搧鏈夊叴瓒o紝鍙仈绯狐/span>涓寳鏋楁牸鑾峰彇銆侟/span>


鍖椾含涓寳鏋楁牸绉戞妧鍙戝睍鏈夐檺鍏徃
鐢佃瘽:鐐瑰嚮&鏌ョ湅
鑱旂郴浜国 搴蜂箰
閭紪: 102208
鍦板潃: 鍖椾含甯傛槍骞冲尯鍖楁竻璺敓鍛界瀛﹀洯鍖楁竻鍒涙剰鍥?-1-102
鍚屽搧鐗屼骇鍝侊細
鐚滄偍鎰熷叴瓒Ⅻ/div>
鎹竴鎵更/a>
鏉ヨ鐧昏
鍏抽棴
璇风暀涓嬫偍鐨勮仈绯绘柟寮忥紝鐧昏瀹屾垚鍗冲彲鏌ョ湅鐢佃瘽涓庝緵搴斿晢鑱旂郴锛屾垨绛夊€欎緵搴斿晢鑱旂郴鎮ㄣ€侟/div>
鐣欒█绫诲瀷锛欬/div>
*濮撳悕锛欬/div>
*鐢佃瘽锛欬/div>
*鍗曚綅锛欬/div>
Email锛欬/div>
*鐣欒█鍐呭锛欬/div>
璇疯鏄庨渶姹傛暟閲忥紝鍨嬪彿瑙勬牸浠ュ強绾害鍚噺绛夎姹傘€
*楠岃瘉鐮侊細
Baidu
map